As digital weighing solution with the converter Connexx®, the load cell Inteco® offers fast signalling times and optimal transparency in dosing and weighing processes. With an output signal of 2 mV/V, load levels of up to 75 t, accuracy classes up to C6 and high-quality stainless steel, it has a wide range of potential applications.

The versatile, innovative weighing solution for silo and vessel weighing

  • Further development of the PR 6201 load cell
  • NEW: Output signal of 2 mV/V
  • NEW: additional load levels 60 t and 75 t
  • NEW: Accuracy class (C6) from 3 t
  • NEW: even higher corrosion resistance
  • All accessories and installation kits of the PR 6201 load cell can still be used

 

 

The Inteco Load Cell was voted as the Reader's Choice Best Load Cell for 2018.

ParameterDescriptionAbbr.D1/NC3C6Unit
Accuracy class0.040.0150,008% Emax
Maximum capacityHighest limit of specified measuring rangeEmaxSee Ordering information tableSee Ordering information tableSee Ordering information tablekg
Safe load limitMaximum load without irreversible damageElimFor 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
For 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
For 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
% Emax
Destructive loadDanger of mechanical destructionEdFor 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
For 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
For 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
% Emax
Minimum LC verificationMinimum load cell verification interval (vmin = Emax/Y)See Accuracy classes and minimum verification interval, vmin table See Accuracy classes and minimum verification interval, vmin table See Accuracy classes and minimum verification interval, vmin table 
For Emax = 500 kgY2,500n.a.n.a.
For Emax = 1 tY5,000n.a.n.a.
For Emax = 2 tY5,00010,000n.a
For Emax = 3 t … 75 tY5,00014,0003 t – 10 t: 14,000
>20 t: 20,000
Rated outputRelative output at maximum capacityCn2mV/V


Datasheet